Worcester boiler no hot water: causes and what to check
When a Worcester Bosch combi gives no hot water, start with the display: a fault code, a blank screen or a flashing light tells you whether the boiler has locked out, lost power or is simply not being asked for hot water. Then check the pressure gauge (roughly 1 to 1.5 bar cold), that other gas appliances work, and in cold weather that the plastic condensate pipe outside has not frozen. If all of those are fine and the heating works but the taps stay cold, the fault is usually inside the boiler, most often the diverter valve, the hot water flow sensor or a scaled plate heat exchanger, and that needs a Gas Safe registered engineer.
Loyal Plumbers · Updated
Discuss your plumbing workFirst, what is the boiler doing?
Worcester Greenstar combis heat water on demand. When you open a hot tap, water flowing through the boiler is detected, the burner lights and heat is sent to the hot water side instead of the radiators. Anything that breaks that chain gives you cold taps, so the quickest way to narrow it down is to notice what the boiler does when you open a hot tap.
Stand by the boiler with someone running a hot tap. Listen for the fan starting and the burner lighting, and watch the display for a tap symbol, a flame symbol or a fault code. Write down any code exactly as shown, including the number after the letters on models that display both. That single detail often saves a return visit.
| What happens | Likely direction |
|---|---|
| Display blank, no lights | Power supply, fused spur or boiler electrical fault |
| Fault code or flashing light, boiler will not fire | Lockout: ignition, pressure, condensate or overheat fault |
| No reaction at all, heating works normally | Flow sensor not detecting the tap, or diverter valve stuck on heating |
| Burner fires but water is only lukewarm | Scaled plate heat exchanger, diverter partly stuck, or temperature set too low |
| Hot for a moment, then cold | Boiler locking out under load, low gas pressure or condensate blockage |
Checks you can safely make yourself
These checks do not involve opening the boiler case and are worth doing before you book anyone. A good share of no hot water calls turn out to be pressure, gas supply or a frozen condensate pipe.
- Pressure: the gauge should read about 1 to 1.5 bar when cold. Many Worcester combis will not fire below their minimum. Top up through the filling loop following your manual, and close it fully afterwards.
- Gas: check the hob lights and, on a prepayment meter, that there is credit. If nothing gas-fired works, the problem is the supply rather than the boiler.
- Hot water temperature: make sure the hot water setting on the control panel has not been turned right down.
- Power: if the display is blank, check the fused spur switch next to the boiler and your consumer unit.
- Reset: if the display shows a lockout, press reset once as your manual describes. If it locks out again, stop there and book an engineer.
- Other taps: try the kitchen tap as well as the bathroom. If only one outlet is cold, the fault is at that tap or shower, not the boiler.
Do not remove the boiler casing or try to free internal parts. Work inside a gas appliance must be done by a Gas Safe registered engineer. If you smell gas, turn off the supply at the meter if it is safe to do so, open windows and call the National Gas Emergency Service on 0800 111 999.
Frozen condensate pipe in cold weather
Greenstar boilers are condensing boilers, and they drain acidic condensate water through a plastic pipe, often running outside to a drain. In a hard frost that pipe can freeze. The condensate then backs up inside the boiler, which shuts itself down and shows a fault. You lose both heating and hot water, usually on the coldest morning of the year.
Worcester publishes guidance on thawing the pipe by pouring warm, not boiling, water along the outside section or holding a warm pack against it, then resetting the boiler. Only do this where the pipe is at ground level and safe to reach. If the pipe runs high up a wall, or it freezes every winter, it may need rerouting or insulating. Our guide to boiler condensate pipe routing explains what a good installation looks like.
Heating works but the taps are cold
If the radiators heat up normally but the boiler ignores a running hot tap, the boiler is healthy enough to fire, so attention moves to the parts that switch it into hot water mode. The flow sensor, sometimes called a turbine or flow switch, tells the boiler that a tap is open. If it sticks or fails, the boiler never knows you want hot water.
The diverter valve then sends heat to the hot water side. If it sticks in the heating position, the boiler may fire when you open a tap but send the heat to the radiators instead, so you may notice radiators warming while the tap stays cold. Both parts sit inside the boiler and the correct replacement depends on the exact model, so an engineer should test them before ordering anything. Our general guide to no hot water but heating works covers the same symptom on other makes of boiler.
Lukewarm water and London's hard water
Much of London has hard water, and limescale builds up inside the plate heat exchanger that transfers heat into your tap water. As the scale thickens, the boiler struggles to pass enough heat across, so the water comes out warm rather than hot, or only hot at a very low flow. The heating is often unaffected.
A scaled plate heat exchanger can sometimes be cleaned, but on older boilers replacement is often the more reliable fix. If scale is the cause, it is worth asking about a scale reducer on the incoming cold supply so the new part does not go the same way. Lukewarm water can also come from a partly stuck diverter valve, so diagnosis matters before parts are bought.
Fault codes that stop hot water
Any lockout stops hot water as well as heating. On many Greenstar models an EA code relates to the flame not being detected, and an E9 code relates to an overheat safety device. The number shown alongside the letters matters, because the same letters can have different meanings depending on the model. Our guides to the Worcester Bosch EA fault and the Worcester Bosch E9 fault explain what to record and why.
Pressing reset once to clear a one-off lockout is reasonable. Resetting it again and again is not a fix, and some faults behind a lockout, such as a gas pressure or flue problem, need checking before the boiler is used normally.
If you have a Vaillant rather than a Worcester, our guide to a Vaillant boiler no hot water covers its codes and checks.
Getting hot water back
If the checks above have not brought the hot water back, book a boiler engineer. Tell us the boiler model from the front label or the data plate under the case, any fault code, the pressure reading, whether the heating still works and whether the problem came on suddenly or has been getting worse. That lets the engineer arrive with a sensible idea of the likely part.
Loyal Plumbers runs 10 vans across London and everywhere inside the M25, 24 hours a day, and all gas work is done by Gas Safe registered engineers. Call or send an enquiry and we will diagnose the fault before recommending a repair. If the boiler is old and parts are hard to get, the engineer will say so plainly, and our guide on whether to repair or replace a boiler covers that decision.
Common questions
- Why does my Worcester boiler have heating but no hot water?
- The boiler is firing, so the usual causes are the flow sensor not detecting the open tap or the diverter valve stuck in the heating position. Both are inside the boiler and need a Gas Safe registered engineer.
- How do I reset a Worcester Bosch boiler?
- Most Greenstar models have a reset button or a reset function on the control panel, described in the user manual. Press it once. If the boiler locks out again, book an engineer rather than resetting repeatedly.
- Can low pressure stop hot water on a Worcester combi?
- Yes. If the pressure is below the minimum in the manual, the boiler may not fire at all. Top it up through the filling loop, and if it drops again, have the leak found.
- Why is my Worcester hot water only lukewarm?
- Limescale in the plate heat exchanger is a common cause in hard water areas like London. A diverter valve that is partly stuck or a low temperature setting can do the same, so it needs diagnosing.
- My Worcester boiler stopped in a frost. What should I do?
- Check the plastic condensate pipe outside. If it has frozen, thaw it with warm, not boiling, water where it is safe to reach, then reset the boiler once.
Sources and further reading
Need help with this in London?
Emergency repairs, investigations and planned installations across London and inside the M25. Tell us what you need so we can agree the next step.
Discuss your job